Quality Documentation
Certificates & Test Reports
Certificates do not make a panel good. They make a supplier checkable. Every card below opens the complete document issued by an independent third party: no summaries, no cropped scans. Five cover factory audits and market access, eight are laboratory reports, all of them issued by SGS-CSTC.
- 13documents on this page
- 5audits & conformity files
- 8SGS laboratory reports
- A2-S1,d0EN 13501-1 fire class
Factory audits & conformity
5 documents
Intertek RESA Audit Summary
Retail Ethical Sourcing audit of the Ningbo factory: machine guarding, PPE training and working conditions, scored by the audit firm.
The Home Depot QSA
Quality System Assessment under the Home Depot retail programme: quality system, packaging control, paint compliance and finish control.
amfori BSCI Monitoring Summary
Full social-compliance monitoring carried out by ELEVATE: workers’ involvement and protection, non-discrimination, fair remuneration.
ICR Verification of Conformity
Conformity verification for flexible stone against EN 12467, EN 13501-1 and EN 13236 under the Construction Products Regulation (EU) 305/2011.
SABER Certificate of Conformity
SASO conformity certificate for artificial stone wall panels under the building-materials technical regulation, part 2: insulation and cladding.
Laboratory performance tests
8 reports · issued by SGS-CSTC, Shanghai and Xiamen
Fire performance, EN 13501-1
A2-S1,d0: limited combustibility, lowest smoke-production category, no flaming droplets. This is the rating specifiers ask for on commercial interiors.
California Proposition 65
Screening of the product against California’s listed-substance requirements, the document US retail buyers ask for first.
VOC content
Volatile organic compounds analysed by HS-GC-MS with reference to US EPA 5021A:2003. Every regulated compound came back below the detection limit.
Freeze-thaw cycling
ASTM C1026, 20 cycles between −3°C and +5°C, three hours at each extreme: no visible damage on any of the five specimens.
Temperature cycling
24 hours at −40°C, then 24 hours at +80°C, then inspection: no evident visible change on the sample.
Impact resistance
Impact test with reference to ISO 10545-5:1997, the standard method for ceramic-type wall coverings. Result: 0.41.
Absorption & density
ASTM C97/C97M-15: water absorption 5.41%, density 1,920 kg/m³. These two numbers are what “lightweight and waterproof” actually means.
Abrasion resistance
ASTM D1044-13, CS-10 wheels at 500 g per wheel, 500 cycles: mass loss 0.0833 g. The surface survives shoe traffic and furniture moves.